• Concrete Mix Design for M55 grade A triple blend mix ...

    Feb 15, 2020· Concrete mix Design for M55 Grade concrete, a Triple Blend with GGBS and Microsilica is as follows; OPC Cement 53 Grade – 330 Kg GGBS – 200 Kg Micro silica – 30 Kg Water Cement ratio (w/c) – Free Water – 140 liters 20mm Metal / Aggregates – 611 Kg 10mm Metal / Aggregates – 475 Kg Crush Sand – 813 Kg Admixture Dosage – % Admixture – Kg Density of Concrete ...

    Get Price
  • ASTM SPECIFICATIONS FOR CONCRETE MASONRY UNITS NCMA

    ASTM C5503 (ref. 9a) included two grades of concrete brick: Grade N for veneer and facing applications and Grade S for general use. In 2006, the grades were removed and requirements for concrete brick used in veneer and facing applications were moved into a …

    Get Price
  • Concrete Mix Design | Different Grades of Concrete

    May 17, 2017· 8 bags of cement required for 1 of M20 grade concrete. 672 kg of Sand required for 1 of M20 grade concrete. 1326 kg of 20mm Aggregate is required for 1 of M20 grade concrete. 200 litres of water is required for 1 of M20 grade concrete. Table for Quantity of Cement, Sand, Aggregate, Water required for Different grades of ...

    Get Price
  • Concrete Mix Design – M60 Grade Of Concrete (OPC 53 Grade)

    Concrete mix design – M60 grade of concrete provided here is for reference purpose only. Actual site conditions vary and thus this should be adjusted as per the location and other factors. A. Design Stipulation: Charastaristic comprehensive Strength 28 days = 60 N/mm 2 Maximum size of aggregate = 20 mm Degree of workability = Collapsible

    Get Price
  • HYTEC Concrete and Calculator

    Special Class Concrete. High strength 65 MPa, 80 MPa, 100 MPa. Commonly used for projects requiring high strength concrete with options in design slump between 140 and 200 mm. 65 MPa concrete is available in 10 mm, 14 mm and 20 mm aggregate sizes while 80 and 100 MPa are only available in 10 mm and 14 mm aggregate size.

    Get Price
  • Mix design of m55 grade concrete as per latest IS code IS ...

    F’ck = fck + factor based on grade of concrete , whichever is higher For M55 grade concrete Factor based on grade of concrete = Standard Deviation = F’ck= 55 + X 5 = N/mm2 F’ck = 55 + = N/mm2. Hence higher value of F’ck = N/mm2 is to be used for design calculations

    Get Price
  • Mix Design M50 Grade Civil Engineering

    Water content per cum of concrete = 144 kg Cement content = 144/ = kg / m 3 Say cement content = 412 kg / m 3 (As per contract Minimum cement content 400 kg / m 3) Hence 5. Calculation for : [ Formula’s can be seen in earlier posts]Volume of concrete = 1 m 3 Volume of cement = 412 / ( X 1000 ) = m 3

    Get Price
  • QUIKRETE Concrete Mix at

    QUIKRETE ProFinish 5000 80lb High Strength Concrete Mix. Item 234135 Model 100785

    Get Price
  • Table of concrete design properties (fcd, fctm, Ecm, fctd ...

    Design values of concrete material properties according to EN199211 Unit weight γ. The unit weight of concrete γ is specified in EN199111 Annex plain unreinforced concrete γ = 24 kN/m concrete with normal percentage of reinforcement or prestressing steel γ = 25 kN/m 3.. Characteristic compressive strength f ck. The characteristic compressive strength f ck is the first value ...

    Get Price
  • Concrete, Cement Masonry – The Home Depot

    The Latexite Airport Grade Driveway Filler Sealer is The Latexite Airport Grade Driveway Filler Sealer is an asphalt emulsionbased lowVOC formula designed to beautify and protect your blacktop driveway. This nonskid sealer fills hairline cracks (1/8 in. or less) and is polymer fortified for added durability.

    Get Price
  • Standard Specification for Anchor Bolts, Steel, 36, 55 ...

    This specification covers straight, bent, headed, and headless anchor bolts (also known as anchor rods) made of carbon, medium carbon boron, alloy, or highstrength lowalloy steel. It provides for anchor bolts in three strength grades, two thread classes, and in the diameters specified in Section specification also covers allthread rod for use in anchoring to concrete.

    Get Price